Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
N Am Spine Soc J ; 18: 100323, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38746017

RESUMO

Background: Postoperative infection is a complication of spinal fusion surgery resulting in increased patient morbidity. Strategies including intraoperative application of powdered vancomycin have been proposed to reduce the incidence of infection; however, such antimicrobial effects are short-lived. Methods: Instrumentation of the L4-L5 vertebrae was performed mimicking pedicle screw and rod fixation in 30 rats. Titanium instrumentation inoculated with either PBS or 1×105 CFU bioluminescent MRSA, along with biomimetic bone grafts infused with varying concentrations of vancomycin and 125 µg of rhBMP-2 (BioMim-rhBMP-2-VCM) were implanted prior to closure. Infection was quantified during the six-week postoperative period using bioluminescent imaging. Arthrodesis was evaluated using micro-CT. Results: Infected animals receiving a bone graft infused with low-dose (0.18 mg/g) or high-dose vancomycin (0.89 mg/g) both exhibited significantly lower bioluminescent signal over the six-week postoperative period than control animals inoculated with MRSA and implanted with bone grafts lacking vancomycin (p=.019 and p=.007, respectively). Both low and high-dose vancomycin-infused grafts also resulted in a statistically significant reduction in average bioluminescence when compared to control animals (p=.027 and p=.047, respectively), independent of time. MicroCT analysis of animals from each group revealed pseudoarthrosis only in the control group, suggesting a correlation between infection and pseudoarthrosis. MRSA-inoculated control animals also had significantly less bone volume formation on micro-CT than the PBS-inoculated control cohort (p<.001), the MRSA+low-dose vancomycin-infused bone graft cohort (p<.001), and the MRSA+high-dose vancomycin-infused bone graft cohort (p<.001). Conclusion: BioMim-rhBMP-2-VCM presents a novel tissue engineering approach to simultaneously promoting arthrodesis and antimicrobial prophylaxis in spinal fusion. Despite mixed evidence of potential osteotoxicity of vancomycin reported in literature, BioMim-rhBMP-2-VCM preserved arthrodesis and osteogenesis with increasing vancomycin loading doses due to the graft's osteoinductive composition.

2.
Spine J ; 23(9): 1389-1399, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37247639

RESUMO

BACKGROUND CONTEXT: Bacterial infection of spinal instrumentation is a significant challenge in spinal fusion surgery. Although the intraoperative local application of powdered vancomycin is common practice for mitigating infection, the antimicrobial effects of this route of administration are short-lived. Therefore, novel antibiotic-loaded bone grafts as well as a reliable animal model to permit the testing of such therapies are needed to improve the efficacy of infection reduction practices in spinal fusion surgery. PURPOSE: This study aims to establish a clinically relevant rat model of spinal implant-associated infection to permit the evaluation of antimicrobial bone graft materials used in spinal fusion. STUDY DESIGN: Rodent study of chronic spinal implant-associated infection. METHODS: Instrumentation anchored in and spanning the vertebral bodies of L4 and L5 was inoculated with bioluminescent methicillin-resistant Staphylococcus aureus bacteria (MRSA). Infection was monitored using an in vivo imaging system (IVIS) for 8 weeks. Spines were harvested and evaluated histologically, and colony-forming units (CFUs) were quantified in harvested implants and spinal tissue. RESULTS: Postsurgical analysis of bacterial infection in vivo demonstrated stratification between MRSA and phosphate-buffered saline (PBS) control groups during the first 4 weeks of the 8-week infection period, indicating the successful establishment of acute infection. Over the 8-week chronic infection period, groups inoculated with 1 × 105 MRSA CFU and 1 × 106 MRSA CFU demonstrated significantly higher bioluminescence than groups inoculated with PBS control (p = 0.009 and p = 0.041 respectively). Histological examination at 8 weeks postimplantation revealed the presence of abscesses localized to implant placement in all MRSA inoculation groups, with the most pervasive abscess formation in samples inoculated with 1 × 105 MRSA CFU and 1 × 106 MRSA CFU. Quantification of CFU plated from harvested spinal tissue at 8 weeks post-implantation revealed the 1 × 105 MRSA CFU inoculation group as the only group with a significantly greater average CFU count compared to PBS control (p = 0.017). Further, CFU quantification from harvested spinal tissue was greater than CFU quantification from harvested implants across all inoculation groups. CONCLUSION: Our model demonstrated that the inoculation dosage of 1 × 105 MRSA CFU exhibited the most robust chronic infection within instrumented vertebral bodies. This dosage had the greatest difference in bioluminescence signal from control (p < 0.01), the lowest mortality (0% compared to 50% for samples inoculated with 1 × 106 MRSA CFU), and a significantly higher amount of CFUs from harvested spine samples than CFUs from control harvested spine samples. Further, histological analysis confirmed the reliability of this novel rodent model of implanted-associated infection to establish infection and biofilm formation of MRSA for all inoculation groups. CLINICAL SIGNIFICANCE: This model is intended to simulate the infection of instrumentation used in spinal fusion surgeries concerning implant locality and material. This model may evaluate potential antimicrobial and osteogenic biomaterials and investigate the relationship between implant-associated infection and failed fusion.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Ratos , Animais , Infecções Estafilocócicas/tratamento farmacológico , Infecção Persistente , Roedores , Reprodutibilidade dos Testes , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/patologia , Antibacterianos/uso terapêutico , Modelos Animais de Doenças
3.
J Neurosurg Spine ; 39(1): 113-121, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37021767

RESUMO

OBJECTIVE: Infuse bone graft is a widely used osteoinductive adjuvant; however, the simple collagen sponge scaffold used in the implant has minimal inherent osteoinductive properties and poorly controls the delivery of the adsorbed recombinant human bone morphogenetic protein-2 (rhBMP-2). In this study, the authors sought to create a novel bone graft substitute material that overcomes the limitations of Infuse and compare the ability of this material with that of Infuse to facilitate union following spine surgery in a clinically translatable rat model of spinal fusion. METHODS: The authors created a polydopamine (PDA)-infused, porous, homogeneously dispersed solid mixture of extracellular matrix and calcium phosphates (BioMim-PDA) and then compared the efficacy of this material directly with Infuse in the setting of different concentrations of rhBMP-2 using a rat model of spinal fusion. Sixty male Sprague Dawley rats were randomly assigned to each of six equal groups: 1) collagen + 0.2 µg rhBMP-2/side, 2) BioMim-PDA + 0.2 µg rhBMP-2/side, 3) collagen + 2.0 µg rhBMP-2/side, 4) BioMim-PDA + 2.0 µg rhBMP-2/side, 5) collagen + 20 µg rhBMP-2/side, and 6) BioMim-PDA + 20 µg rhBMP-2/side. All animals underwent posterolateral intertransverse process fusion at L4-5 using the assigned bone graft. Animals were euthanized 8 weeks postoperatively, and their lumbar spines were analyzed via microcomputed tomography (µCT) and histology. Spinal fusion was defined as continuous bridging bone bilaterally across the fusion site evaluated via µCT. RESULTS: The fusion rate was 100% in all groups except group 1 (70%) and group 4 (90%). Use of BioMim-PDA with 0.2 µg rhBMP-2 led to significantly greater results for bone volume (BV), percentage BV, and trabecular number, as well as significantly smaller trabecular separation, compared with the use of the collagen sponge with 2.0 µg rhBMP-2. The same results were observed when the use of BioMim-PDA with 2.0 µg rhBMP-2 was compared with the use of the collagen sponge with 20 µg rhBMP-2. CONCLUSIONS: Implantation of rhBMP-2-adsorbed BioMim-PDA scaffolds resulted in BV and bone quality superior to that afforded by treatment with rhBMP-2 concentrations 10-fold higher implanted on a conventional collagen sponge. Using BioMim-PDA (vs a collagen sponge) for rhBMP-2 delivery could significantly lower the amount of rhBMP-2 required for successful bone grafting clinically, improving device safety and decreasing costs.


Assuntos
Fusão Vertebral , Masculino , Ratos , Humanos , Animais , Fusão Vertebral/métodos , Transplante Ósseo/métodos , Microtomografia por Raio-X , Biomimética , Ratos Sprague-Dawley , Fator de Crescimento Transformador beta/farmacologia , Fator de Crescimento Transformador beta/uso terapêutico , Proteína Morfogenética Óssea 2/farmacologia , Colágeno/farmacologia , Proteínas Recombinantes/farmacologia , Vértebras Lombares/cirurgia
4.
J Pediatr Orthop ; 42(6): e590-e595, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35442932

RESUMO

BACKGROUND: Loeys-Dietz syndrome (LDS) is a rare autosomal-dominant connective tissue disorder caused by genetic mutations in the transforming growth factor-ß (TGFß) signaling pathway. In addition to vascular malformations, patients with LDS commonly present with bone and tendon abnormalities, including joint laxity. While TGFß signaling dysregulation has been implicated in many of these clinical manifestations, the degree to which it influences the tendinopathy and tendon healing issues in LDS has not been determined. METHODS: Wound healing after patellar tendon transection was compared between wild-type (WT) and Tgfbr2-mutant (LDS) mice (7 mice per group). In all mice, the right patellar tendon was transected at midsubstance, while the left was untouched to serve as a control. Mice were euthanized 6 weeks after surgery. Tendon specimens were harvested for histopathologic grading according to a previously validated scoring metric, and gene expression levels of Mmp2, Tgfb2, and other TGFß-signaling genes were assayed. Between-group comparisons were made using 1-way analysis of variance with post hoc Tukey honestly significant difference testing. RESULTS: Expression levels of assayed genes were similar between LDS and WT tendons at baseline; however, at 6 weeks after patellar tendon transection, LDS tendons showed sustained elevations in Mmp2 and Tgfb2 compared with baseline values; these elevations were not seen in normal tendons undergoing the same treatments. Histologically, untreated LDS tendons had significantly greater cellularity and cell rounding compared with untreated WT tendons, and both WT and LDS tendons had significantly worse histologic scores after surgery. CONCLUSION: We present the first mechanistic insight into the effect of LDS on tendons and tendon healing. The morphologic differences between LDS and WT tendons at baseline may help explain the increased risk of tendon/ligament dysfunction in patients with LDS, and the differential healing response to injury in LDS may account for the delayed healing and weaker repair tissue. LEVEL OF EVIDENCE: Level V.


Assuntos
Síndrome de Loeys-Dietz , Ligamento Patelar , Fator de Crescimento Transformador beta2 , Animais , Modelos Animais de Doenças , Síndrome de Loeys-Dietz/genética , Metaloproteinase 2 da Matriz , Camundongos , Ligamento Patelar/fisiopatologia , Ligamento Patelar/cirurgia , Tendões/fisiopatologia , Tendões/cirurgia , Fator de Crescimento Transformador beta2/genética , Fator de Crescimento Transformador beta2/fisiologia , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...